Home / Products

Product catalogue

Specifications below are typical supply ranges used on our projects. Final models are confirmed after a site survey. Filter the grid, then scroll into full detail sheets.

ABC dry powder extinguishers
Extinguishers

ABC dry powder extinguisher

Multi-purpose stored-pressure extinguisher for ordinary combustibles, flammable liquids, and energized electrical equipment at a safe distance. Standard issue for offices, stores, and plant corridors.

Capacities1 kg, 2 kg, 4 kg, 6 kg, 9 kg
AgentMonoammonium phosphate (ABC)
CertificationISI marked · typical IS 15683 range
ServiceAnnual refill, 5-year hydrostatic test window
Best forWarehouses, parking, general industry

Request this model

CO2 extinguisher on a wall
Extinguishers

CO2 extinguisher

Clean, non-conductive discharge for electrical rooms, CNC cells, and panel boards. Leaves no powder residue on sensitive equipment.

Capacities2 kg, 4.5 kg, 6.5 kg, 9 kg, 22.5 kg trolley
AgentCarbon dioxide
HornFrost-protected discharge horn
Use classB and electrically energized fires
CautionVentilate after discharge; asphyxiation risk in small rooms

Request this model

Firefighting foam operations
Extinguishers

AFFF foam extinguisher

Aqueous film-forming foam for hydrocarbon spill risk: diesel yards, paint stores, and loading bays. Forms a vapour-sealing blanket on liquid surfaces.

Capacities6 L, 9 L portable · 50 L trolley
ConcentrateAFFF 3% / 6% as specified
Not forEnergized electrical equipment unless rated
Pair withSpill kits and drain isolation

Request this model

Box of smoke detectors
Detection

Modular photoelectric smoke detector

Low-profile optical detector for offices, hotels, and residential towers. Compatible with conventional and addressable panels we commission on site.

SensingPhotoelectric chamber
ProfileLow-profile ceiling mount
Wiring2-wire / 4-wire as per panel
OptionsSounder base, remote LED, isolator
MaintenanceAnnual sensitivity check, chamber clean

Request this model

Industrial process piping
Detection

Rate-of-rise / fixed heat detector

Used where smoke detectors would nuisance-alarm: kitchens (beyond hoods), boiler rooms, dusty shops, and parking ramps.

ModesFixed temperature and rate-of-rise
Typical set point57°C / 80°C class as designed
EnvironmentHigher humidity and airborne dust
LoopSame panel as smoke and MCP

Request this model

Industrial control hardware
Detection

Fire alarm control panel

Conventional or addressable FACP with zone LEDs, battery backup, and outputs for sounders, strobes, and HVAC shutdown.

Types2–32 zone conventional · addressable loops
StandbySealed batteries sized to code
OutputsNAC, relays, BMS / EMS interface
HandoverCause-and-effect matrix + as-built

Request this model

Data centre requiring clean agent
Suppression

Clean agent gas suppression

Total-flood systems for server rooms, UPS rooms, and archives. Designed around enclosure integrity, nozzle layout, and abort/release stations.

AgentsFM-200 / Novec 1230 class (project specific)
DetectionCross-zoned smoke, pre-discharge tone
CylindersStored in dedicated plant with weigh check
TestsRoom integrity / door fan as specified

Request this model

Commercial kitchen line
Suppression

Kitchen wet chemical system

Hood, plenum, and duct nozzles with fuel shut-off. Suited to hotels, cloud kitchens, and industrial canteens.

AgentWet chemical, Class K / F cooking oils
ActuationAutomatic fusible links + manual pull
InterlockGas / electric appliance shut-off
ServiceSemi-annual inspection typical

Request this model

Commercial high-rise
Suppression

Sprinkler heads & alarm valves

Pendent, upright, and sidewall heads with wet or dry alarm valves for warehouses and office towers.

TempsOrdinary, intermediate, high as hazard class
K-factorSelected per hydraulic calculation
CoverageOH1–OH3 / storage as designed
WaterTank + pump set sized to demand

Request this model

Red fire hydrant
Accessories

Landing valves & hydrant fittings

Internal and external hydrant valves, couplings, and branch pipes for NBC-aligned hydrant networks.

Size63 mm instantaneous typical
MaterialGunmetal / SS as specified
PressureTested to project hydrostatic spec
InstallStair core, yard hydrants, terrace

Request this model

Emergency equipment housing
Accessories

Fire hose box & first-aid hose reel

Weatherproof cabinets for RRL hose, branch pipe, and keys. Indoor reels for occupant first response.

CabinetMS powder-coated or SS 304
Hose15 m / 30 m RRL with couplings
Reel20–30 m rubber hose, shut-off nozzle
FinishSignal red with bilingual labels

Request this model

Warehouse requiring wayfinding
Accessories

Photoluminescent safety signage

Exit, assembly, extinguisher, and hydrant signs sized for corridor viewing distance. Glow-in-dark finishes for power-loss conditions.

TypesExit, fire point, assembly, directional
MaterialPhotoluminescent rigid sheet
FixingWall, flag, and hanging
PackFloor-wise kits after walkthrough

Request this model